Using a Spectrex Flame Simulator is the only sure way to perform a full functionality test on your SharpEye Flame Detectors.
Using an external, portable Spectrex Flame Simulator is the best means to perform a full functionality, “end to-end” test of the detector and the fire protection system without the need to start a real fire (which is not permitted in hazardous areas and can be dangerous in non-hazardous areas).
The Spectrex Flame Simulator is the only safe method to test the flame detector’s sensors, internal electronics, alarm activation software, cleanliness of the viewing window/lens, wiring integrity, actual relay activation and proper functionality of any other outputs used (mA, RS485, HART).
Spectrex Flame Simulators are ATEX certified EExd for use in Zone 1 hazardous areas and are powered by rechargeable NiCad batteries. When fully charged, the Fire Simulator will operate for at least 50 tests without recharging.
Hazardous Area Approval: ATEx approved Ex II 2G, Nemko 02ATEx255; EExd IIB T5 (50°C), IP67
Charge: 400mA for 14 hours
Model selection:
- 20/20-310 Flame Simulator for Triple IR (IR3)
- 20/20-311 Flame Simulator for UV & UV/IR
- 20/20-312 Flame Simulator for Single IR
- 20/20-313 Flame Simulator for Multi-R
Read more here
Sensor Check Gas Kit by GDS Technologies Ltd UK
Calibration Kit - Regulator (fixed flow 1 ltr/min), tube (3M length), test gas applicator cap and test gas bung plus can / case.
Flammable Gases |
|
||
009 |
600 |
Test Gas Cylinder Methane |
50% LEL in air |
" |
750 |
Test Gas Cylinder Propane |
50% LEL in air |
" |
610 |
Test Gas Cylinder Butane |
50% LEL in air |
" |
720 |
Test Gas Cylinder Pentane |
20% LEL in air |
" |
810 |
Test Gas Cylinder Acetylene |
50% LEL in air |
004 |
760 |
Test Gas Cylinder Hydrogen |
20% LElL in air |
|
|
Refrigerant Gases |
|
009 |
710 |
Test Gas Cylinder R22 |
R22 in air |
" |
770 |
Test Gas Cylinder R134a |
500ppm in air |
" |
605 |
Test Gas Cylinder R152a |
500ppm in air |
|
|
Toxic Gases |
|
009 |
620 |
Test Gas Cylinder Carbon Monoxide |
50ppm in air |
" |
630 |
Test Gas Cylinder Carbon Dioxide |
1% in nitrogen |
" |
640 |
Test Gas Cylinder Hydrogen Sulphide |
10ppm in air |
" |
650 |
Test Gas Cylinder Sulpher Dioxide |
5ppm in nitrogen |
" |
660 |
Test Gas Cylinder Ammonia |
25ppm in air |
" |
670 |
Test Gas Cylinder Nitric Oxide |
25ppm in air |
" |
680 |
Test Gas Cylinder Nitrogen Dioxide |
5ppm in air |
" |
690 |
Test Gas Cylinder Ethylene Oxide |
5ppm in nitrogen |
" |
740 |
Test Gas Cylinder Hydrogen Chloride |
1ppm in air |
" |
800 |
Test Gas Cylinder Chlorine |
10ppm in air |
" |
700 |
Test Gas Cylinder Nitrogen |
100% |
" |
780 |
Test Gas Cylinder Oxygen in N2 |
10% Oxygen in Nitrogen |